>I'm curious at the order of magnitude spread of values from Typical to Max., >especially as it's not configuration dependent.Temperature? Isn't leakage exponential with (absolute) temperature. For things like battery life, many times you have to consider real operating temperatures rather than worst case if you want sensible answers. More fun for the people making and reading data sheets. -- The suespammers.org mail server is located in California. So are all my other mailboxes. Please do not send unsolicited bulk e-mail or unsolicited commercial e-mail to my suespammers.org address or any of my other addresses. These are my opinions, not necessarily my employer's. I hate spam.
Low-power FPGAs?
Started by ●October 25, 2004
Reply by ●October 25, 20042004-10-25
Reply by ●October 25, 20042004-10-25
Symon, That is the latest data. The reason for the leakage is source drain leakage across the smallest geometry transistors. Since we do have a lot of transistors, we have to be very careful to use the leakiest versions only where needed for speed, and use the higher Vt transistors for non-speed paths and circuits (like the memory cells). One can select for the lowest current devices (which will also be the slowest speed devices), but that is a bad business model, as getting slow parts regularly is not something you necessarily want! As geometries shrink, leakage increases (per sq-micron). As well, process variations also increase, so there may be a larger variation in the latest generations than in earlier generations for both typical and maximum numbers. So the typ of 20 mA for a 2VP2 at room temperature is just that, typical process. The max at 300 mA at 100C is the fastest corner part/process number at the hottest temperature. The current at 85C would be about 2.5X the current at 25C (both from simulations and data). So, the same part would be typically 20 mA at room, and 50 mA at 85C. There is a small variation with pattern. Not large enough to matter (when compared to process variations). V4 has a low static (leakage) current (much much lower than other 90nm ICs) because of the triple oxide process we used. So the memory cells are all 0.13 micron, and the same as the V2P generation (in terms of leakage). If you are interested in a specific part, I could go see where the process is currently running, and provide you with data. Austin Symon wrote:> Hi Austin, > http://direct.xilinx.com/bvdocs/publications/ds083.pdf > Page 73 of 425. > I'm curious at the order of magnitude spread of values from Typical to Max., > especially as it's not configuration dependent. > Anyway, if you have some new leakage figures, could you let me know where to > find them? > Thanks, Symon. > "Austin Lesea" <austin@xilinx.com> wrote in message > news:cljagp$pkn1@cliff.xsj.xilinx.com... > >>Symon, >> >>The leakage current is not pattern dependent. >> >>Make sure you check the latest datasheet, as we used to state all >>leakages at 100C worst case (theoretical) silicon. We now state what we >>see from the process control sampling over all actual process corners. >> >>Austin >> > > >
Reply by ●October 25, 20042004-10-25
Austin, Thanks for that, it's much clearer now. Of course, as Hal also says, the temperature makes a big difference. I seem to recall you've posted along these lines before, sorry to make you repeat yourself. I'm looking forward to when the V4 datasheet gets filled in. Until then, I'll now use the leakiest parts I buy in either the fastest circuits I design or the ones used in fridges! ;-) Best, Syms. "Austin Lesea" <austin@xilinx.com> wrote in message news:cljf2b$52g1@cliff.xsj.xilinx.com...> Symon, > > That is the latest data. > > The reason for the leakage is source drain leakage across the smallest > geometry transistors. Since we do have a lot of transistors, we have to > be very careful to use the leakiest versions only where needed for > speed, and use the higher Vt transistors for non-speed paths and > circuits (like the memory cells). > > One can select for the lowest current devices (which will also be the > slowest speed devices), but that is a bad business model, as getting > slow parts regularly is not something you necessarily want! > > As geometries shrink, leakage increases (per sq-micron). As well, > process variations also increase, so there may be a larger variation in > the latest generations than in earlier generations for both typical and > maximum numbers. > > So the typ of 20 mA for a 2VP2 at room temperature is just that, typical > process. The max at 300 mA at 100C is the fastest corner part/process > number at the hottest temperature. > > The current at 85C would be about 2.5X the current at 25C (both from > simulations and data). So, the same part would be typically 20 mA at > room, and 50 mA at 85C. > > There is a small variation with pattern. Not large enough to matter > (when compared to process variations). > > V4 has a low static (leakage) current (much much lower than other 90nm > ICs) because of the triple oxide process we used. So the memory cells > are all 0.13 micron, and the same as the V2P generation (in terms of > leakage). > > If you are interested in a specific part, I could go see where the > process is currently running, and provide you with data. > > Austin
Reply by ●October 25, 20042004-10-25
Symon wrote:> Simon, > I guess it's been a while since you checked out the quiescent supply > currents for the latest parts? For example, worst case Iccintq for the > smallest V2PRO (XC2VP2) is 300mA. That's about 20 hours on a NiMH D cell. > Typical is 20mA, but no-one would design with typical figures, would they? > BTW, anyone know why there's such a big difference from 'typical' to 'max' > figures? Does it depend on the configuration used in the part? > Cheers, Syms.Yes, the typical figures clock only 15% or so of the available flipflops. Rene -- Ing.Buero R.Tschaggelar - http://www.ibrtses.com & commercial newsgroups - http://www.talkto.net
Reply by ●October 25, 20042004-10-25
John wrote:> I am working on an instrument that currently uses a 300 MHz TI dual- > issue DSP + A/Ds + a micro. Under "normal" use, I can get a week out of > the D-cell batteries the device uses. > > At the moment, I am considering replacing the DSP and other glue with an > FPGA, but I don't see many low-power options. > > Any suggestions? Any low-power FPGA experiences to share? > > I asked an Altera FAE and he very rudely answered "Low-power Altera > FPGAs aren't on the road map"...yeah and I bet low-power CPLDs (ala > MaxII) weren't on the road map until CoolRunner started hurting sales... > > I'd like to stick with brand A or X since they offer soft core > processors.You should clarify how much usage, or up time, each block is expecting. Low power is not a direction FPGAs are heading, see the values in this thread of 20 or 40mA typical, 2.5x multiplier for 85'C Tj (thermal run-away anyone :) Wider supply specs are common in uC, but we may start to see this in FPGA data : they must have some lower RAM_Vcc, which is the Min to keep CONFIG, but at very low/stopped clock speeds, and then the higher operate Vcc. Austin: Any numbers on a Config_Keep Vcc (no Clock), and the Static Icc at that operate point ? This is the same as RUN/IDLE in uC designs. For longest battery life, expect to use a good Low Power uC for operator interface, system management, and run the higher power stuff only when you have to. -jg
Reply by ●October 25, 20042004-10-25
John wrote:> > I am working on an instrument that currently uses a 300 MHz TI dual- > issue DSP + A/Ds + a micro. Under "normal" use, I can get a week out of > the D-cell batteries the device uses. > > At the moment, I am considering replacing the DSP and other glue with an > FPGA, but I don't see many low-power options. > > Any suggestions? Any low-power FPGA experiences to share? > > I asked an Altera FAE and he very rudely answered "Low-power Altera > FPGAs aren't on the road map"...yeah and I bet low-power CPLDs (ala > MaxII) weren't on the road map until CoolRunner started hurting sales... > > I'd like to stick with brand A or X since they offer soft core > processors.The Altera guy told you right. The FPGA market is driven by density which requires the latest processing geometries, meaning the smallest. The last generation or two have started to ramp up the quiescent power to a point where there is little chance of having a "low power" FPGA any time in the future. Any new low power devices will only be "low" in relative terms. If you want to consider an FPGA, look to the older families. The Altera ACEX parts are much lower power than the newer stuff, at least when you are not clocking them. You will have to figure out how large your design will be to determine the dynamic power. If there are down times for the FPGA processing, would it be possible to power the FPGA off while keeping the user interface running? The FPGA can be reconfigured very quickly so that the user would not be able to notice it. That is something I am doing on our boards, power to the DSP and power hog FPGA are dropped to put the board in a low power mode where just a power controller MCU and an ACEX FPGA are running. This puts power down to < 10 mW and yet the board can respond to external command to power back up within a few 10's of mS. -- Rick "rickman" Collins rick.collins@XYarius.com Ignore the reply address. To email me use the above address with the XY removed. Arius - A Signal Processing Solutions Company Specializing in DSP and FPGA design URL http://www.arius.com 4 King Ave 301-682-7772 Voice Frederick, MD 21701-3110 301-682-7666 FAX
Reply by ●October 25, 20042004-10-25
Jim, We can keep the memory contents of the 4VLX25 all the way down to where the configuration logic recognizes a power down condition (runs around ~0.6 V). Now, to be sure, we have not characterized everything down that far (0.6V), but we did do all characterization for functionality tests from 1.0V to 1.4V, so we know for sure we are safe inside this region (memory contents stay). If someone had a killer app that needed beaucoup parts, we would consider binning for lower numbers. Some people are considering operating at the 1.2V nominal, and then 'sleeping' at 1.0V. The sleeping is just all clocks stopped (disabled). Static current is about half as much compared to 1.2V. So let us say you were at 100 mA at 1.2V, that takes you down to maybe ~55mA at 1.0V. 60 mA for 10 hours is 600 mA-Hr, which is not so bad from a power point of view in a battery operated device. With the 1V, that is 600mW-Hr. AA NIMH batteries are ~ 2000 mA-Hr (1.2V) which is pretty close to 2000 mW-Hr. So with 6 of these, and a good 90% efficient switching power supply, you could have ~10,000 mW-Hr of power. Given that you have to do something some of the time, you then have to go to full 1.2V ON, and then do something useful. That will then make the power jump up to something a bit larger (depending on what you are doing). Let us suppose you allow yourself 1 ampere in the work hard mode, or 1200 mW per hour when doing something. Then you can figure out how much time you can be doing something, vs sleeping. If it is a handheld SDR radio, there is also a 5W transmitter (typical), so you have another 10,000 mW per hour of talk time (assuming a reasonably efficient transmitter). There is also Vccaux (Iccaux) at 2.5V, and Vcco at ??V to consider as well. Austin Jim Granville wrote:> John wrote: > >> I am working on an instrument that currently uses a 300 MHz TI dual- >> issue DSP + A/Ds + a micro. Under "normal" use, I can get a week out >> of the D-cell batteries the device uses. >> >> At the moment, I am considering replacing the DSP and other glue with >> an FPGA, but I don't see many low-power options. >> >> Any suggestions? Any low-power FPGA experiences to share? >> >> I asked an Altera FAE and he very rudely answered "Low-power Altera >> FPGAs aren't on the road map"...yeah and I bet low-power CPLDs (ala >> MaxII) weren't on the road map until CoolRunner started hurting sales... >> >> I'd like to stick with brand A or X since they offer soft core >> processors. > > > You should clarify how much usage, or up time, each block is expecting. > > Low power is not a direction FPGAs are heading, see the values in this > thread of 20 or 40mA typical, 2.5x multiplier for 85'C Tj > (thermal run-away anyone :) > > Wider supply specs are common in uC, but we may start to see this in > FPGA data : they must have some lower RAM_Vcc, which is the Min to keep > CONFIG, but at very low/stopped clock speeds, and then the > higher operate Vcc. > > Austin: Any numbers on a Config_Keep Vcc (no Clock), and the > Static Icc at that operate point ? > > This is the same as RUN/IDLE in uC designs. > For longest battery life, expect to use a good Low Power uC for operator > interface, system management, and run the higher power stuff only when > you have to. > > -jg >
Reply by ●October 25, 20042004-10-25
Austin Lesea wrote:> Jim, > > We can keep the memory contents of the 4VLX25 all the way down to where > the configuration logic recognizes a power down condition (runs around > ~0.6 V). > > Now, to be sure, we have not characterized everything down that far > (0.6V), but we did do all characterization for functionality tests from > 1.0V to 1.4V, so we know for sure we are safe inside this region (memory > contents stay). If someone had a killer app that needed beaucoup parts, > we would consider binning for lower numbers. > > Some people are considering operating at the 1.2V nominal, and then > 'sleeping' at 1.0V. The sleeping is just all clocks stopped (disabled). > > Static current is about half as much compared to 1.2V. So let us say > you were at 100 mA at 1.2V, that takes you down to maybe ~55mA at 1.0V.Sounds like that could be well worth the effort. ( and maybe even 0.75V ? ) <snip>> > There is also Vccaux (Iccaux) at 2.5V, and Vcco at ??V to consider as well.Only some devices have Vccaux - can that be removed, or does it need to be reduced ? Vcco I presume can be removed on selected banks, if you realled needed to, but the Static Icc on IO cells should be very low, as they are relatively few - correct ? -jg
Reply by ●October 26, 20042004-10-26
Forget a V2PRO... unless you need a power PC... there are far cheaper options to get a processor. I also never suggested using bleeding edge... if you pick an 'older part' you will find the static current better... it just won't have the same capability as the modern 90 nm parts.. although cyclone (cough cough) seem to have a lower quiescent current 12mA - 80 mA.. but they probably cheated to get that. And even tho A or X seems good what about Q ? Quicklogic Eclipse is a low power (not so) FPGA .. so they might be via OTP... so you prototype with RAM based... but you can't beat the 22 - 250 uA quiescent current... and only 100mA at 100Mhz. Don't forget the option of powering down when not in use, use a coolrunner to turn the FPGA off if necessary / possible just don't forget to shut down I/O too.. or the saving will be killed by protection diodes. Older FPGA's have smaller configurations and can be programmed fast if you externally clock them. And yea.. design to typical.. select of test even :-) unless your running at -20 or +60C .. but at 0C you NiMH battery life will be half that at 20C too.. Then pick a better battery... heard of lithium ion? :-) You might also want to watch the D cells.. often the are a 'C' cell in side a cardboard wrapper. There are also special 'radio modeller' NiCAD's that have rather nice mAH ratings... designed for electric cars and planes. I have a battery pack here good for 600mA hours @ 8.4V... not much bigger than a D cell. Simon "Symon" <symon_brewer@hotmail.com> wrote in message news:2u4nrqF26i2edU1@uni-berlin.de...> Simon, > I guess it's been a while since you checked out the quiescent supply > currents for the latest parts? For example, worst case Iccintq for the > smallest V2PRO (XC2VP2) is 300mA. That's about 20 hours on a NiMH D cell. > Typical is 20mA, but no-one would design with typical figures, would they? > BTW, anyone know why there's such a big difference from 'typical' to 'max' > figures? Does it depend on the configuration used in the part? > Cheers, Syms. > > "Simon Peacock" <nowhere@to.be.found> wrote in message > news:417cd164@news.actrix.gen.nz... > > FPGA's by their very nature are low power.. provided you don't clockthem> > fast. > > > > >
Reply by ●October 26, 20042004-10-26
Faster and smaller generally comes out a little ahead of larger slower in my experience. The trade off between clock speed and area is more or less a wash because power is proportional to clock frequency, however there are second order effects to consider. First, a smaller design means the routing can be more localized. Routing distance is roughly proportional to the square root of the area. Secondly, a parallel design, at least for arithmetic has extra routing orthogonal to the signal path and extra gating to handle the carry functions. This extra logic and associated routing makes the v-F curve non-linear. Austin Lesea wrote:> Hal, > > Let's see....P= CV^2F, and so for each node switching, the power scales > with frequency. > > One node at F is equal to two nodes at 1/2F? Yes, it sure looks that way. > > I suppose the reason to run slower is to run cooler. > > But, you are right, run the smallest part as fast as needed to do the work. > > No reason to run it any faster than needed, however. > > One reason for the very low power for the DSP48 is that the capacitive > loads are very small. > > Good catch. > > Thanks, > > Austin > > Hal Murray wrote: > > >>FPGAs are very efficient for doing the work (dynamic power), but high > >>clock speeds means lots of power. Better to make the algorithm highly > >>parallel, and lower the clock rate as much as possible. > > > > > > What's going on here? Classic reasoning says that 2 FFs at half > > speed will take the same power as 1 FF at full speed. (assuming > > same cap load...) > > > > Why not run faster so you can use a smaller part and get lower > > static power? > >-- --Ray Andraka, P.E. President, the Andraka Consulting Group, Inc. 401/884-7930 Fax 401/884-7950 email ray@andraka.com http://www.andraka.com "They that give up essential liberty to obtain a little temporary safety deserve neither liberty nor safety." -Benjamin Franklin, 1759