Make sure you have set your smartmodel mappings in your modelsim.ini file
(end of it). These mappings are used by Modelsim to find out were the
compiled smartmodel library is located. Also have a look on the Xilinx
website which contains lots of info on how to use RocketIO with Modelsim :-)
Hans
www.ht-lab.com
--
Regards,
Hans.
"shalini" <shalini_rao27@yahoo.co.in> wrote in message
news:bb192883.0408310354.538b339f@posting.google.com...
> When doing behavioral simulation using modelsim 5.8b SE version for
> rocket io
> i am getting the warning as
> # No default binding for component 'gt_fibre_channel_4'(no entity
> gt_fibre_channel) was found.
>
> and all the outputs of mgt are having the value 'U'.
Reply by Mike Treseler●August 31, 20042004-08-31
shalini wrote:
> When doing behavioral simulation using modelsim 5.8b SE version for
> rocket io
> i am getting the warning as
> # No default binding for component 'gt_fibre_channel_4'(no entity
> gt_fibre_channel) was found.
A default binding means that
the component AND
the entity AND
the instance code all use the same
identifier 'gt_fibre_channel_4'
and all are compiled and in scope.
A vhdl configuration is an alternative
to a default binding. Good luck.
-- Mike Treseler
Reply by shalini●August 31, 20042004-08-31
When doing behavioral simulation using modelsim 5.8b SE version for
rocket io
i am getting the warning as
# No default binding for component 'gt_fibre_channel_4'(no entity
gt_fibre_channel) was found.
and all the outputs of mgt are having the value 'U'.