> What is "cold sparing"? I've never heard the term.
>
If the device is powered off, the I/O's appear as high impedance. Then you
can hook two devices together, one as a spare, and power off the one not being
used at the time. In the application that I am considering, there are several
sections of the system, not all of which are powered all the time, and I don't
want to load down the source if I (sink) is powered off.
There's probably a more formal definition somewhere. But with typical CMOS
I/O, you get a diode to the supply rail which can be problematic (also
consider PCI systems with clamp diodes).
--
rk, Just an OldEngineer
"These are highly complicated pieces of equipment almost as complicated as
living organisms. In some cases, they've been designed by other computers. We
don't know exactly how they work."
-- Scientist in Michael Crichton's 1973 movie, Westworld
Reply by TC●October 29, 20052005-10-29
"rk" <stellare@nospamplease.comcast.net> wrote in message
news:Xns96FE6565322E1rk@216.196.97.136...
> Hi,
>
> Don't happen to have an LVDS specification (EIA-644) handy and couldn't
> find a
> freebie on the www. So hopefully someone out there has one.
>
> Here's the question, I was told that section 4.4.2, & 6 have the fail-safe
> requirements. The issue is whether cold sparing capability is an LVDS
> requirement. I don't recall it being a requirement but I do want to go to
> the
> documentation to be sure.
>
> My design does have cold sparing capability, it's the right thing to do
> for
> this particular application, so that is not an issue.
>
> It is critical that the intent of the system designers, who state that
> they
> want cold sparing capability, be properly documented in the requirements
> (many
> users geographically and organizationally diverse) to avoid an oops.
> Having a
> specification buried in a third level referenced document that is not easy
> to
> obtain is a good opportunity for an oops.
>
> But if cold sparing isn't part of the EIA-644 specification, then the top
> level specification that the systems guys are writing needs to be updated.
>
> Thanks in advance,
>
> --
> rk, Just an OldEngineer
> "These are highly complicated pieces of equipment almost as complicated as
> living organisms. In some cases, they've been designed by other computers.
> We
> don't know exactly how they work."
> -- Scientist in Michael Crichton's 1973 movie, Westworld
What is "cold sparing"? I've never heard the term.
TC
Reply by rk●October 29, 20052005-10-29
Hi,
Don't happen to have an LVDS specification (EIA-644) handy and couldn't find a
freebie on the www. So hopefully someone out there has one.
Here's the question, I was told that section 4.4.2, & 6 have the fail-safe
requirements. The issue is whether cold sparing capability is an LVDS
requirement. I don't recall it being a requirement but I do want to go to the
documentation to be sure.
My design does have cold sparing capability, it's the right thing to do for
this particular application, so that is not an issue.
It is critical that the intent of the system designers, who state that they
want cold sparing capability, be properly documented in the requirements (many
users geographically and organizationally diverse) to avoid an oops. Having a
specification buried in a third level referenced document that is not easy to
obtain is a good opportunity for an oops.
But if cold sparing isn't part of the EIA-644 specification, then the top
level specification that the systems guys are writing needs to be updated.
Thanks in advance,
--
rk, Just an OldEngineer
"These are highly complicated pieces of equipment almost as complicated as
living organisms. In some cases, they've been designed by other computers. We
don't know exactly how they work."
-- Scientist in Michael Crichton's 1973 movie, Westworld