Hi all, I'm using a cyclone EP1C6 Q240 and want to instanciate a pll, but using the PLL2 (input are CLK2 and CLK3). My problem is that with the design assistant, i can create a macro-function called altpll, but i can't choose the input i want (clk2, on pin 153 of EP1C6Q240 ). how should i do ? regards, -- Ceci est une signature automatique de MesNews. Site : http://www.mesnews.net
cyclone's pll
Started by ●February 21, 2005
Reply by ●February 21, 20052005-02-21
The mega function created has a pin called input (or similar). You simply connect this to a device pin, and then assign the location you need for the CLKn pin. "GL" <a@b.c> wrote in message news:mn.ab807d527b734006.23732@b.c...> Hi all, > I'm using a cyclone EP1C6 Q240 and want to instanciate a pll, but using > the PLL2 (input are CLK2 and CLK3). My problem is that with the design > assistant, i can create a macro-function called altpll, but i can't choose > the input i want (clk2, on pin 153 of EP1C6Q240 ). > > how should i do ? > > regards, > > -- > Ceci est une signature automatique de MesNews. > Site : http://www.mesnews.net >
Reply by ●March 10, 20052005-03-10
Reply by ●March 10, 20052005-03-10