Hi, Is there an Altera application to count the number of equivalent gates for Logic Elements, Memory, DSP blocks, PLL etc... ? Thanks... I don't find this information..
Stratix II - Cyclone II GATE COUNT
Started by ●April 20, 2007
Reply by ●April 20, 20072007-04-20
On 20 Apr., 16:09, vhdldesigner.patr...@gmail.com wrote:> Hi, > > Is there an Altera application to count the number of equivalent gates > for Logic Elements, Memory, DSP blocks, PLL etc... ? > > Thanks... > > I don't find this information..its not available - it's called: "marketing strategy"... Antti
Reply by ●April 23, 20072007-04-23
On 20 apr, 16:09, vhdldesigner.patr...@gmail.com wrote:> Hi, > > Is there an Altera application to count the number of equivalent gates > for Logic Elements, Memory, DSP blocks, PLL etc... ? > > Thanks... > > I don't find this information..Here is the PR-article where they announce to stop comparing to gates... Altera: Out with Gate Counts, In with Logic Elements http://www.altera.com/corporate/news_room/releases/releases_archive/2001/products/pr-logic_measurement.html Altera devices are Macrocells, Logic Elements or Adaptive Logic Modules. The combinatorial complexity of the primitive elements vary and they hold 1, 1 or 2 bits in the register. So depending on your register count or combinatorial complexity you end up with a specific device, where from my experience the I/O pin, OnChip memory or DSP Block count is leading the device choiche. Greatings, Karl.